Description
- Size (sensor): 50mm (W) x 50mm(D) x 70mm(H)
- Weight: 130g (excluding cable)
ZIP File
- Supply voltage: 12VDC/24VDC (Operation range 10 to 30V ripple within 10%)
- Supply current: 150mA or less (during start up 450mA is necessary.)
- Light source: Laser semiconductor (905nm) Laser class 1 (IEC60825-1:2007)
- Accuracy: ±40mm
- Repeated accuracy: σ< 30mm
- Scan angle: 270°
- Angular resolution: 0.25°
- Start up time: Within 10 sec (start up time differs if malfunction is detected during start up)
- Input: IP reset input, photo-coupler input (current 4mA at ON)
- Output: Synchronous Output, photo coupler open collector output 30VDC 50mA MAX.
- Interface: Ethernet 100BASE-TX
- LED display: Power supply LED display (Blue): Blinks during start up and malfunction state.
- Ambient temperature: -10°C to +50°C
- Ambient Humidity: Below 85%RH (without dew, frost)
- Storage temperature: -30°C to +70°C
- Storage Humidity: Below 85%RH (without dew, frost)
- Shock resistance: 196m/s2 (20G) X,Y and Z direction 10 times.
- Protective Structure: IP65
- Material Front case: Polycarbonate, Rear case: Aluminum
- Surrounding intensity: Less than 15,000lx
Detection range
- 0.06m to 10m (white Kent sheet)
- 0.06m to 4m (diffuse reflectance 10%)
- Max. detection distance : 30m
EMC standards
(EMI)
- EN61326-1: 2013
- EN55011: 2009 + A1: 2010
(EMS)
- EN61326-1: 2013
- EN61000-4-2: 2009
- EN61000-4-3: 2006 + A1: 2008 + A2: 2010
- EN61000-4-4: 2012
- EN61000-4-6: 2009
- EN61000-4-8: 2010
Estimate shipping