- 1x Micro Load Cell (0-780g) - CZL611CD
Sensor
- Controlled By: Bridge Input
- Sensor Type: Shear Load Cell
- Weight Capacity Max: 780 g
- Maximum Overload: 936 g
- Creep: 7.8 g / hr
- Zero Balance: ± 78 g
- Cell Repeatability Error Max: ± 390 mg
- Cell Non-Linearity Max: 390 mg
- Cell Hysteresis Max: 390 mg
- Temperature Effect on Span: 39 mg / °C
- Temperature Effect on Zero: 39 mg / °C
Electrical
- Rated Output: 1 mV / V
- Rated Output Error Max: ± 100 μV / V
- Output Impedance: 1 kΩ
- Supply Voltage Max: 10 V DC
Physical
- Operating Temperature Min: -10 °C
- Operating Temperature Max: 40 °C
- Material: Aluminium Alloy
- Screw Thread Size: M4